Technical data of the monoturn absolute rotary encoder CVS78E
General specifications
causality
Detailed information
Detection type
optical sampling
Equipment type
Singleturn absolute rotary encoders
Functional Safety (MTTFd)
25 a, L10: 7.7 E+9 (at 3000 rpm)
Operating voltage (U_B)
10 ... 30 VDC
No-load supply current (I_0)
350 mA max.
biometrics
16-bit ± 2 LSB, 13-bit ± 1 LSB, 12-bit ± 0.5 LSB
output code
binary code
Interface Type
CANopen
decision (of a congress)
Single turn: up to 16 bits, overall: up to 16 bits
transmission rate
Maximum 1 MBit/s
standards-compliant
Communication profile: DS 301, device profiles: DS 406 and DS 417
approx. 2600 g (combination 1), approx. 3900 g (combination 2)
rotation speed
Maximum 3000 min^-1
moment of inertia (mechanics)
180 g cm^2
Starting torque
≤ 4 Ncm
shaft load
Axial: 60 N, radial 80 N
connectivity
causality
Detailed information
cable connection
∅ 10.2 mm, Radox 9 x 0.5 mm²
terminal block
Optional, see ordering information
operating mode
operating mode
clarification
polling mode
The connected host requests the current location value via a teleport request message.
recurrent mode
The encoder sends the current position value cyclically without the need for host prompting.
synchronous mode
The encoder sends the current position value after receiving the synchronization message from the host.